This transcription covers a discussion on AI infrastructure and energy, featuring Amin Vadaat, Chief Technologist for AI Infrastructure at Google. The conversation highlights that trillions are being invested in clean energy and AI infrastructure, shaped by markets, policy, and capital. Google’s massive CAPEX ($175-185 billion in 2025) dwarfs U.S. transmission spending and major projects like Vogtle nuclear plant. Data centers have scaled from 10 megawatts to gigawatts, but as AI shifts from training to inference, smaller deployments (tens to hundreds of megawatts) may become viable due to lower scale needs for inference and geographic locality for latency and reliability. Reliability requirements are not intrinsic; lower reliability (e.g., two-nines) with double capacity can be more cost-effective. Behind-the-meter power serves as bridge power for rapid deployment, but grid-connected capacity is preferred long-term. Google has signed demand response agreements for gigawatts of flexibility, allowing utilities to provision for peak demand. The goal is energy abundance, but current constraints mean overcapacity is unlikely soon. The podcast "Critical Capital" explores these themes further.
Trillions of dollars are flowing into clean and critical infrastructure, but those investments aren't driven by technology alone. They're shaped by markets, by policy, by capital, and by the institutions that connect them. I'm Alfred Johnson, CEO of Crocs and host of a brand new podcast, Critical Capital. Each episode I talk with people deploying capital, shaping policy and building the clean economy. Tune in as we unpack how progress is actually made. Tune into Critical Capital on Spotify, Apple, or wherever you get your podcasts. Catalyst is supported by Fish Tank PR, an award-winning PR firm focused on climate and energy tech, renewables, and sustainability. Fish Tank is known for generating prominent and effective media coverage for the brands they work with. If you want a PR partner that's thoughtful, shoots straight, and gets results, you'll like Fish Tank PR. To learn more about Fish Tank's approach, visit fishtankpr.com. When utilities need flexible capacity, they can count on, they turn to Energy Hub. Energy Hub works with more than 170 utilities, coordinating over 2.5 million devices to manage 3.4 gigawatts of flexibility, built for the moments when utilities can't afford uncertainty. Energy Hub builds and operates virtual power plants that utilities actually stake their grid planning on, coordinating EVs, batteries, thermostats, and more through a single platform, built for utility scale. Predictive, verifiable, and designed to perform when it counts, learn more at EnergyHub.com. Latitude Media, covering the new frontiers of the Energy Transition. I'm Shail Khan. Welcome to Catalyst Life. Thank you so much. Okay, I am here with Amin Vadaat, who's sitting next to me here. Amin is the Chief Technologist for AI Infrastructure at Google. Amin, welcome. Thank you for having me, excited to be here. Okay, I want to provide a little bit of context for the conversation we're about to have here. I know this is why everybody is here in this room at this conference, but there's a lot going on in AI infrastructure at the moment, particularly as it pertains to Energy. Amin leads the infrastructure team at Google. So in the Q4 2025, earning this report, Google announced its intent to spend somewhere between $175 and $185 billion in CAPEX this year. It's not all for AI infrastructure, but let's assume a decent portion of it is just for this purpose right now. Let me offer you some context for that number. We had a big election in Hungary this week. That number is roughly the GDP of Hungary. Numbers that are more relevant to this audience probably. We spend about $25 or $35 billion a year in CAPEX on electricity transmission infrastructure in the United States. So this is five to seven times that amount just from Google just in one year. If you want to talk about big infrastructure projects, let's talk about Voguell. Voguell is the notoriously expensive, extremely expensive nuclear plant that's the first nuclear project built in the United States in decades. Voguell cost about $30 billion. So this is five or six Voguell per year. If you want to move outside, energy is just for one fund one. I was in San Diego last week, which was happened to be when the lunar mission dropped down. So I looked up NASA, NASA's annual budget is $25 billion. So this is seven NASA's that I mean is responsible for spending each year or at least this year on infrastructure. So with a lot of infrastructure and with great CAPEX comes a lot of great questions, I have many. Let's dive into some of them. The first one I mean, I guess is one of the big ones that's been on my mind and I want your perspective on it. We clearly have been living in a world where scale of individual data centers has been a driving force, right? We've gone from you guys were probably building tens of megawatts per data center years ago, 200 megawatts to now gigawatts. And I think probably everybody here appreciates that for training purposes, for model training purposes, scale is really important. This is why we're getting these huge data centers. But for inference, I've heard mixed things as we shift more in the inference world, it may or may not be true that you need that level of individual scale. So in your mind, how much does scale matter when it comes to inference computer? Why does that scale? I mean scale of the individual data center. Yeah, it's a great question. And I think you have it spot on. I remember when Google announced its first data center in Oregon, the Dallas, this was 23, three, four years ago, before I was at Google, 10 megawatts. And people were just stunned that a little company would go build a 10 megawatt data center. That was a big number. And actually, no one else was building data centers for their own computer infrastructure at the time. And it's just grown from there, 100 megawatts, gigawatts, etc. It's a really good question in terms of the split between training and serving. And so here's where, to me, it gets perhaps most interesting. At the scale that we're operating, we want the latest, greatest, most efficient, most capable training cluster, essentially on an annual basis. If you look at our announcements for TPUs and videos announcements for GPUs, the latest greatest is coming out every year. And every year, the latest greatest is, by definition, better than last year. Let's pick this gigawatt number. Let's say you buy the latest greatest and you put a gigawatt somewhere. And maybe you put a couple of these down. After a few years, one, two, probably not much more than that, whoever is doing the training is going to want the new latest greatest. And then they're going to want to gigawatt somewhere else. Now you've got to gigawatt a capacity that used to be used for training. What are you going to do with it? Probably going to serve on it. And so now the question is, could you get away with lower scale? Yes, absolutely. And in fact, we have lots of smaller deployments, lots of data centers with much less than a gigawatt capacity, 10 megawatts. And that serves equal value for inference. Inference in general, now for our largest, most capable models, they are going to run on many chips. It's not just one chip, simultaneously. But you don't strictly need a gigawatt capacity to be able to do use for work. You probably don't even need 100 megawatts of capacity. It gets a little bit more interesting than that because of, let's say, co-located compute and storage and networking and everything else. In other words, it's not just the accelerator. But no, strictly speaking, you could go to much smaller deployments and still be able to do inference. The lifecycle aspect of it that I just described, there's people cycle workloads over the capacity is the more interesting one in terms of the footprint for serving. So there's two interesting pieces to that. One is, as you're saying, just intrinsically for inference, you don't need the same scale effect. But there is probably some minimum scale. There's viable, as you said, because you are co-locating it with other things. So you're probably not doing 10 kilowatt deployments. No. Okay, so we're in the tens of megawatts, or hundreds, but not gigawatts necessarily. And these racks today are trending toward hundreds of kilowattts, just these things. For the rack. For the rack with multiple chips in it. But I mean, it's, actually, you're going to need some minimum scale. Okay. And then the second interesting piece is what you said about repurposing. And there, I guess, it's a question of demand, right? You put a few gigawatts for training. You move on to the next few gigawatts for training of whatever the next GPU or GPU is. But is that enough to serve the booming? I think the assumption has been, look, we're training now, but that is going to result in the inference demand shooting upward. Yeah. Right? And so then that would imply it's not nearly going to be enough. Exactly. And so this is, and I think we're at that transition point. I mean, we've said last year that we're entering the age of inference, I think, with agents exploding today. That's well, well happening. So probably, I mean, the analogy I would use is from Google's early days with web search. It used to be that most of the compute that Google was dedicated to building the search index. Pretty quickly, you hoped, and unfortunately, not to be true, that most of the capacity to be used to serve that index. Same thing here. Most of our capacity, maybe earlier on, was used for building the model. But you would hope that it transitions to serving the model pretty quickly. And you're absolutely right that we're there. So I do think that over time, also, as the efficiency and latency of these models improves, our disparate deployments are going to be valuable. So what I mean by that is today, each individual token that is generated by the model takes a reasonable amount of latency. So much so that actually you might not be able to tell the difference here. Let's say in San Francisco, if you're accessing content on the East Coast, maybe even Europe's in times, relative to San Francisco. In general, for let's say maps or search or ads, that's not true. But computing is sufficiently efficient and latency sufficiently low that you will notice because of the speed of light propagation delay of the network if you're going to a far way site. So as these services become more interactive, as they become more efficient, and that is still going to be a journey. We're not there today. You're going to want to have geographic locality. That's also going to impact reliability. Because again, you can think of it as a highway system. The less distance you have to go, the more likely it is that you're going to find the capacity you need for your request. So I guess wrapping up this piece of it, the core question that I've been trying to think about, I think a lot of folks in this world that intersects energy and AI have been thinking about as well, is do we end up as we should?
shift more and more into inference where you could make an argument for smaller pixel sizes, making sense for data centers. Does it end up being easier in three years, five years, something like that? To go build a new gigawatt data center and find a site on the grid that you can interconnect the gigawatt data center, or does it become easier and or faster to build 50, 20 megawatt data centers? Or something like that? - Yeah, that's a good question. In general, we found over the years that it's easier to build a smaller number of larger sites. There's still asterisk there. You don't want to be too concentrated, again, from a fault tolerance and geographic locality perspective. In other words, the argument of build as big a site as you can in one place breaks down rather quickly. But having 1,000 each with 0.1% of your capacity has other overheads associated with it in terms of management. So I think that it'll really come down to geographical locality and probably a medium number of medium sized data centers or sorry for the whatever lack of precision there. But medium number of medium sized data centers augmented with a small number of large data centers. - Right, which makes sense. Okay, so then the next question spent on my mind about the future of this infrastructure that has a lot of direct relevancy to the energy side of the equation is about reliability. Data centers historically have been, just it's gospel, I would say. The data centers require the highest reliability three nines or whatever the number is and to the extent where like the standard footprint of a normal data center in cloud world, pre-AI, but even the early AI data centers as well has a UPS system and backup generators and all this kind of stuff just to make sure that reliability is that high. Two questions for you. One, why? Why is the reliability requirement so high? And two, is there any argument for that changing in the future because that reliability requirement causes so much challenge and capex, right? Why is it such a problem that we have lead times on gas generators, all this kind of stuff? It is because of the reliability requirement. So is it intrinsic to something about what you're doing or is it just a function of how the business has evolved? - Yeah, fantastic question. And I think that if I were probably send one message here is no, it is not intrinsic and we should be thinking about lower reliability, power delivery overall. I'll tell you why it has been, but I think that I'll also get to why it has changed substantially. So for most modern software services, the compute is actually a relatively small fraction of your cost. And so now it makes sense to over-provision it. You wanna have 99.9%, 99%, 5.9% reliability for your software services. You don't need quite that, but many of our data centers aim for four-nines of minutes of downtime, a year, maximum, which as you said, has a large amount of cost associated with it. Now, if you think about it though, as of now, given how constrained resources are and how costly they are, a much larger fraction of your overall service cost is in the compute. So if you want to your internal customers, if I were to go to my internal customers and said, would you rather have four-nines of availability? And half the capacity, or two-nines of availability, and twice the capacity, which do you pick? Very often, not always, very often they'll say, oh my gosh, give me two extra capacity. And if I need to have 99%, 99% sounds good, you all know the math, that's 3.65 days of downtime a year. That's a lot. Like we're saying, three and a half a week every year, you're down, you don't have the capacity. But if the other 51 and a half weeks, I get twice the capacity. Many people would say, sign me up. And yet, I don't see that happening. Is it happening? And I'm not seeing it. Without saying too much, it's happening. I would say that's actually the co-design there with our customers at Google has been one of our sources of significant efficiency. OK, so that's a good segue then into my next question, which is behind the meter power generation storage, whatever it might be. There are multiple reasons that one might put something behind the meter, right? And it can be for reliability purposes. That is one. But oftentimes, now people are talking about bridge power and things like that. What is your view on this? There's an enormous amount of planned behind the meter power. Is that the direction of travel? Will it be the direction of travel for an extended period of time? It's a very important opportunity for us. And it is one of latency, again, a different kind of latency. In other words, what is the time to delivery of capacity? What I'll say though, before going down that path is that we would actually, at Google, prefer a grid connected capacity. Why? I was going to say, why is it my reliability? It is in the end provisioning for a given level of reliability. If you're behind the meter, you're going to have to do all that provisioning yourself. Now, an aspect of this that's actually quite powerful for us to give an example going back to the reliability question in March, we actually had a significant milestone in agreements with utilities for a gigawatt of demand response across our fleet. What does demand response mean? It means that for the utility, for the one week of the year where they have maximum demand, we're willing to brown down. And that also goes to the availability commitment that we make to our customers. Why? Because that allows them to provision not for their worst coldest, hottest, whatever it is a week of the year. But to then provision for the 90, whatever it is, 8% up. And we'll give up that capacity in exchange for, well, in the end, more availability of power less cost, both for us, but also for the ratepayers in the region. So now, if we have to do that, all the reliability work ourselves rather than being able to shift capacity back and forth when we're not using it, like, let's say that we actually have behind the meter power generation. And we will behind the meter in quotes, what if we can, when we're not using it, give it back to the utility? In general, the way we look at it is, we like behind the meter if it means that we get the capacity up most quickly. But we're always going to look to invest with the utilities to bring the transmission. Maybe it's a year after. Maybe it's two years after. But the point is, this gets us the capacity we need. And maybe we need some bridge power in the interim. But that bridge power, actually, in the limit, could be mobile. - Tying these two things together. One thing I haven't fully wrapped my head around with bridge power is the reliability question, right? If you're still in this world where you're demanding, let's say it's not four nines. Let's say it's two nines of reliability. But you need two nines of reliability with just onsite generation for some period of time. However long that bridge is, you gotta build a lot of onsite stuff, right? You end up over provisioning really heavily. And then eventually you get the grid connection and now what do you do with all this stuff? So is there, during that bridge power period, are you offering a different level of service somehow or are you actually provisioning for your two nines, whatever your ultimate reliability requirement is gonna be, but from day one with onsite resources? - It's both, I mean, we basically, I mean, one way to look at it is that most people have trouble unless they've operated at scale thinking in terms of these numbers of like, what's the difference between 99.9 and 99.5 or 99.99 in a given year? And a given year they might actually be identical. And so some people are just gonna say, I'm gonna roll the dice. I hope I get lucky. And sometimes they will. And they actually won't experience any issues. What I would say though is that we also look to seeing, okay, beyond some of this bridge power that we're gonna need, what are the more permanent sources? Would we use solar, wind, nuclear, other sources that will be permanent? But might not be able to get us all the way to the power capacity that we might need. And then we have to augment with whatever, might be turbines, gas or something else. Which could be mobile, as you said. - It could be mobile. - Yeah. I guess the question for me then is, do you feel that we're gonna end up with all this stranded, on-site generation as a result of this? Are we gonna end up with, is there any world where we build excess generating capacity? Or are we just so far underwater now that it doesn't matter? - You know, I'd love to have that problem. I'd love to have that problem. I think that, you know, one of the things that we aim for at Google, and I think you all as well, is a world of energy abundance. And I think that the world would be a better place if energy were abundant. It's not. I'm not just saying that AI or data centers are anything. Energy is a limiter. I think we're so far away from that world that I'd love to have the conversation. I don't think it's the next few years where we have too much. We're living through a profound economic shift. And energy sits at the center of all of it. Trillions of dollars are flowing into power plants, transmission lines, battery factories, data centers, but the future of energy isn't shaped by technology alone. It's shaped by markets, by policy, by capital, and by the institutions that connect them. I'm Alfred Johnson, CEO of Crocs, the capital platform for the Clean Economy. Join me for my brand new show Critical Capital. As I talk with people deploying capital, shaping policy and building projects, together we impact how risk is priced, how incentives are structured, and how progress is actually made. Listen to Critical Capital on Spotify, Apple, or wherever you get your podcasts. - Are you tired of overpaying for big name PR firms? But not really knowing what they're delivering is your comp's team wasting time reviewing lengthy messaging briefs and decks, instead of engaging journalists or producing content? Are you wondering why your competitors are getting press and you aren't?
Fishtank PR is an award-winning climate and energy tech, renewables, and sustainability-focused PR firm dedicated to elevating the work of both early stage and established companies. Whether you need to position yourself as a thought leader in between project announcements or translate complex ideas and technologies into tangible, compelling stories that resonate with the media, Fishtank can help. Check out fishtankpr.com, that's f-i-s-c-h-fishtankpr.com. Virtual power plants are becoming a reliable way for utilities to manage capacity. But enrolling devices is just the start. What really matters is confidence. Knowing those resources will perform when dispatched and being able to prove it, from the control room to the living room. Energy Hub's platform handles the full picture, from near real-time forecasting, locational dispatch, and the kind of rigorous verification that holds up when regulators, grid operators, or leadership ask, did it deliver? Easy enrollment creates momentum. Proven performance builds trust. That's why more than 170 utilities rely on energy hub to manage over 2.5 million devices, delivering 3.4 gigawatts of flexible capacity. See what that looks like at energyhub.com. Let's talk about the different resources that you might put behind the meter. You mention you can build on site, solar wind or whatever, you can do nuclear, you can get your generation that way, you can get your generation with gas as well, and then you can build batteries to buffer. Do these end up the ones that you are going to build that do have on site infrastructure beyond just the UPS and the backup generator? Do they end up looking like little microgrids? And are you optimizing against a bunch of resources? Or is it generally going to be? A lot of some of the data centers, like, I don't know, the XAI data center that got built, is just a bunch of gas generators, basically. The microgrid and the software control here is going to be absolutely key. And this is a place where I think we, as a community, are under-invested today. So if you think about that demand response scenario, I talked about if we need to do a brown down, it's not going to be that the whole site goes away. So I'm okay, maybe we need to give up 20%, 30%, 40% of our capacity. Okay, which 20%, 30% and 40%? What's the signal to the software? What do we drain from where? What SLOs do we shift? Do we say, you know, what for the next week? We're going to need to fail over 20% of requests from this location to somewhere else. Maybe actually a whole building gets powered down for a week, maybe, or most of the building. The microgrid is going to look exactly like this microgrid. And now can you distribute the power dynamically, also, by the way, in response to the workload? I talked about training versus serving. The power footprint, the two are very different. And I assume the latency sensitivity is super different as well. Even within, as you said, even within inference, there are some things that are going to be super latency sensitive and some that very much will not. If you got your overnight agent running, then you might, it might be all serving, but it might be batch serving that's not sensitive from a human and loop perspective. But then others, or your chat interactions, or whatever, that might be very latency sensitive. Is there an extent to which you are sort of uniquely capable of executing on this in the sense that Google is certainly the most vertically integrated player? Are you from the TPUs, through the cloud service, you have Gemini, you're running your own workloads, and so on? So if part of what is required in order to reach this future where data centers are flexible and can operate it, slightly lower reliability, and all those kinds of things, if part of what's required is that you have to differentiate amongst the workloads such that some can operate as necessary, at really low latency and others at higher latency, Google can kind of do all that in-house. I mean, you have customers for Gemini, so you have to serve those customers. But you have more capability than most. How do you think it disseminates out, Bian Google? So I think that it's a good question. It's something that we think a lot about. In other words, what we want to do is we want to design and to end systems that take and together create capabilities. This word, capability is actually essential to what we discuss internally a lot. So I appreciate the question. Create capabilities that otherwise wouldn't be possible. And I do think that it comes down to this vertical integration. In other words, for us, or let's say our TPUs, we co-design them with the building. We co-design them with the power generation source. We co-design them with the deep mind team that builds Gemini models. So it's the software above the models above that, the chip design, by which we do in my team as well. That's integrated with the rack. That's integrated with the data center. That's integrated with the power source. And if between each of these boundaries, you have a custom-optimized interface that gets you a few percent. Those few percent up and down start adding up multiplying out, in fact, to something meaningful. And that is exactly what we go after. OK, so I'm going to ask you to rank some things. There's been a little bit of a debate publicly that I've found interesting about what is the rate limiter on the growth of PI. Let's assume, for the moment, it's not demand. The relative to supply today that there's essentially infinite demand. And maybe that changes at some point in the future. I'd be interested in your perspective on if and when that might happen, but certainly not the case today. So it's going to be something else. There has been an argument that it is chips in the chip supply chain, particularly some of the things upstream in the chip supply chain, like UV tools for lithography and so on. This is a room full of power rant. People, there's certainly also an argument that it is power. I think there's a third argument maybe that it could be labor at some point. You can add a fourth if you want to that. But if you had to rank order, what is the biggest rate limiter to growth between power, chips, and labor? How would you rank them? Yeah, and I would add data center construction and delivery as an EPC as a broad category, not just labor. You may have. Yes. Labor is one component of it, but I think just even the supply chain there associated with electricals, mechanicals, cooling, et cetera, is another aspect of it beyond the chip supply chain. I would say that when delivering the end-to-end, we unfortunately don't have the luxury of focusing on a single limiter. I would say very sincerely and honestly, at 10 AM, it's labor, at noon, it's power, and at 2 PM, it's chips, every single day. I'm going to force you to answer the question a different way. You're supposed to spend whatever it is, $175,000,000,000,000, this year, building out new infrastructure. If you woke up tomorrow and Sundar said, you got to spend 300 now, what would you go try to solve? I think I know that I'm not trying to dodge the question, but I very sincerely feel that actually, we'd have to go scale all of them and that every single one of those is at the limit of what we can do for the envelope that we have. Is one of them inherently easier to scale than the others, among the options. Honestly, all three of those are major, major issues for us. I'm sure that there is an answer, but I'm not relaxed about any of them. This is a real thing. I couldn't pick one. I would say, Sundar, wow, 300. OK, I'll get back to you. Has to what the exact issues are going to be. On the labor and EPC one, curious or perspective on not just related to data center construction, but in general, where the rise of physical AI as a category, the rise of robotics, and who knows what form factor that it ends up taking, has been a second wave. There was an LLM wave of excitement in the public. I'm sure in your world it's been going on longer, but I would say we had this wave of digital AI excitement and now a physical AI wave as well. Do you ever hear a stick in your head for how demand shapes up between those two or how infrastructure will get built relative to those two? Yeah, it's a good question. I mean, I think that in terms of the digital side, rather than the physical side, the demand, obviously, today is much, much, much larger. The architecture for the physical side is still in development. I would say the best examples of it right now are with self-driving cars. In other words, if you think about it, these self-driving cars really are robots on four wheels. And for this use case in particular, you can imagine this is actually one of the hardest use cases. Safety is paramount. Safety is absolutely paramount. And what that means is that you actually give up some capability, some scale, for certainty and reliability. And to my knowledge, without speaking about any of the specifics, this means actually more of the edge use cases are relevant there because the multiplexing associated with cloud is probably less desirable. Those if you have a blip and you're really counting on some computation, if you're doing a chat and whatever your chat app is down for five seconds, fine. Do something else for five seconds, you come back. If the robot can't get its answer in five seconds, depending on the use case, that could be catastrophic. How much of that happens on device, or in the case of a WEMO in car? How much of the computer that occurs in a WEMO or in a humanoid robot in the future is going to happen inside that instantiation of the physical AI device versus getting pulled from the cloud? Without talking about any specific use case, I believe that a lot of it is going to have to be on device and dedicated to that use case. Not all, again, there's going to be different kinds of use cases if it's--
What kind of music do I want to play for my passenger? I don't know. Maybe that's okay if that blips for a few seconds. But if it's, which turn do I take now in a base of maneuver? It seems like you want that on device. Right. Which then makes the argument for like the edge infrastructure stuff a little bit weaker. The thing, people have made the argument back to the edge versus medium size, medium number versus hyper scale thing. I think that people thought the strongest argument for edge edge, small localized compute was things like Waymo, right? But if the really sensitive safety oriented stuff for the really latency sensitive stuff is all going to happen on device, then maybe when you pull, you can handle the latency of going to these coasts. It's a very good question. So I think the, and I would need to think through it more. But if you think about some other related use cases like factory automation, in that case, you have an edge deployment, something that looks more like edge deployment that handles this provision for handling 100 or 1000 or whatever it is robots for that particular use case at the edge. Again, good question. I'm giving you an authority to do so. No, in that case, it might be, you might do that for cost saving reasons, right? Putting all that computing into every individual robot, expensive or power. Right. Because this, I mean, putting that much computing into every one of these robot arms may be prohibitive. Right. For the infrastructure inside the robot. Yes. I want to finish up by asking you something that I feel like I don't hear as much talk about as you'd expect in the long term that there should be, which is, which is CAPEX and cost savings in data center infrastructure. You know, you're going to, right now, we're just in the world of like, we need to build as much as we possibly can. And it seems like speed is the only thing that matters. But in the long arc of history, one presumes ultimately the cost of that CAPEX is going to be important. Where do you see the biggest opportunities? If you think out into the future, how do you turn? If you were to build the same amount of capacity in five years in megawatts as you are today, is there a world where you turn that $175,000, $185,000 into $100,000? And what are the things that could get you there? We're looking at this all the time. I mean, in other words, it is probably one of the biggest focus areas in my team. I won't say biggest, but it's top three for sure. It might be biggest. So in other words, when we say we're spending X dollars, we're saying that if we have had to have done this work last year, we would have to have spent 1.2 X, making up the number. Don't take it as another words. Every year, we're looking to deliver substantial efficiency such that if we had to do it again, it would be way more efficient. This starts with software. And again, a lot of opportunity on the software side. But lots of opportunity on the hardware side. Let me give a very simple example. What is the ratio of power to space in your data center? In other words, if you have, let me pick a number, 100 megawatts. How big a building do you build? And how big a building do you build for 25-year lifetime of that building? Not just one generation of TPU or GPU or whatever, but maybe five or six generations of them. Now you could be conservative and build an infinitely sized, whatever it is building, and say, okay, whatever comes next, I'm going to be set. Or maybe I have to, now if you think about the watts per linear flip of a disk rack versus a GPU rack, radically different. Like, I don't know, 100 X, between disks and GPU. What are you going to assume? So now if we could actually co-design and optimize and say, you know what, this building is going to be a GPU building. That building is going to be a TPU building, and that building is going to be a disk building. Huge opportunity. Now, I've now limited my fungibility. Like if I change my mind in five years' time, and I have a disk building and I want to put some TPUs there, there's going to be a lot of empty space, a lot of empty space. So I think we figure these things out, not perfectly, but every year, every generation, we're looking to drive that co-design for that optimization and managing the flexibility while optimizing the cost. You know, it's interesting on the outside, I think I would have assumed that you had already basically optimized to the T for linear area density. Everybody talks so much about that density inside these data centers for a variety of reasons. Some of that is because for training, it's a performance thing, but for cost reasons as well. I would have assumed you're already at the maximum possible density given today's technology. It sounds like you're saying that hasn't always been the case in part because we've been designing data centers to be more, I don't know, multi-purpose tools. Exactly. And back, I would say five years ago, ten years ago, it didn't pay to have that hyper optimized because if you lost anything in flexibility in a world where compute wasn't the dominant portion of your cost. If compute is not the dominant portion of your cost, you actually want to have flexibility and fungibility. When compute becomes a more dominant portion of your cost, you now actually are thinking, OK, what am I going to do for this year, next year, and the year after to make sure that I optimize it super well? And the difference between storage and compute was at most 10x. The difference between storage and accelerators are approaching 100x. So the problem just got, and getting wider. Now, this is not consuming any more power. Every generation that accelerators are. So these kinds of problems, but even within an accelerator. If you look at the power footprints, and this is where the microgits also come in, of serving versus training, radically different. Like, did you just look at how much power we draw from the utility or from our batteries or from whatever, for one workload versus another? Could be a factor of two. Well, in the profile, those workloads are very different, right? Training sort of notoriously, very on-off, spiky, and you have these, you solve for that. I don't know if this is still true within Google's data centers, but you solve for that by basically blank workloads to try to make it smooth. We don't do this, but yes, there's some do. Yeah. The profile of those workloads, ultimately impacts. What other infrastructure you need on site, what your buffer system, all the power infrastructure, all those kinds of things. Yes. All right. I mean, this was very fun, very informative as I expected. Thank you so much for being here. Thanks for having me. This was great. The mean VDOT is the chief technologist for AI infrastructure at Google. This shows a production of latitude media. You can head over to latitudemedia.com for links to today's topics. This episode is produced by Max Savage-Levinson, mixing in theme song by Sean Markwan. Steven Lacey is our executive editor. I'm Shale Khan, and this is Catalyst.
Podcast Summary
Key Points:
Trillions of dollars are flowing into clean energy and AI infrastructure, driven by markets, policy, capital, and institutional connections, not just technology.
Google plans $175-185 billion in CAPEX for 2025, partly for AI infrastructure, which is five to seven times U.S. annual electricity transmission spending.
AI data centers have grown from 10 megawatts to gigawatts, but inference workloads may require smaller, more distributed sites (tens to hundreds of megawatts) rather than massive clusters.
Data center reliability requirements (e.g., four-nines) are not intrinsic; lower reliability (e.g., two-nines) with higher capacity may be preferred as compute costs rise.
Behind-the-meter power is used for rapid capacity deployment (bridge power), but grid-connected capacity is preferred long-term; demand response agreements with utilities offer flexibility.
Summary:
This transcription covers a discussion on AI infrastructure and energy, featuring Amin Vadaat, Chief Technologist for AI Infrastructure at Google. The conversation highlights that trillions are being invested in clean energy and AI infrastructure, shaped by markets, policy, and capital. S.
transmission spending and major projects like Vogtle nuclear plant. Data centers have scaled from 10 megawatts to gigawatts, but as AI shifts from training to inference, smaller deployments (tens to hundreds of megawatts) may become viable due to lower scale needs for inference and geographic locality for latency and reliability. , two-nines) with double capacity can be more cost-effective.
Behind-the-meter power serves as bridge power for rapid deployment, but grid-connected capacity is preferred long-term. Google has signed demand response agreements for gigawatts of flexibility, allowing utilities to provision for peak demand. The goal is energy abundance, but current constraints mean overcapacity is unlikely soon.
The podcast "Critical Capital" explores these themes further.